OM3 Duplex SC UPC to SC UPC Bend-Insensitive Patch Cable, 1 m, LSZH
F-tone Networks OM3 Duplex SC UPC to SC UPC Bend-Insensitive Patch Cable, 1 m, LSZH. Details are taken from the stored sheet only. Datasheet on request.
- Connector-1
- SC UPC
- Connector-2
- SC UPC
- Fiber Mode
- 50/125 m
- Fiber Type
- Duplex
- Jacket Material
- LSZH
- Jacket Color
- Aqua
Reference model FT-1M-OM3-9 in your inquiry. Datasheets are confirmed offline before order. Full specifications ↓
Technical parameters
| Connector-1 | SC UPC |
|---|---|
| Connector-2 | SC UPC |
| Fiber Mode | 50/125 m |
| Fiber Type | Duplex |
| Jacket Material | LSZH |
| Jacket Color | Aqua |
| Cladding Diameter | 125/1 m |
| Mandrel Radius | 15mm@850nm/7.5mm@1300nm |
| Macrobend Loss@850nm(2 turns) | Induced Attenuation 0.3dB |
| Macrobend Loss@1300nm(2 turns) | Induced Attenuation 0.5dB |
| Operating Temperature | -40 ~ 75C |
| Storage Temperature | -45~85C |
| Fiber Class | G657A1/G657A2 |
| RoHS Compliancy Status | Compliant |
| 当需要在角落和狭小空间内布线时,例如在现有建筑物中的 FTTH 安装中、网络正常运行时间至关重要的数据中心中。 例如,OM4 RBS 跳线在被柜门挤压时将继续提供数据服务,而传统 OM4 跳线会丢失服务 | POP、MDU 分配点和用户连接中的 FTTH 布线当需要小半径安装或布线可能会受到偶尔的小半径事件的影响时 |
| Designation | Fiber Dia.( m) | Type | Fast Ethernet 100BASE-FX | 1 Gigabit Ethernet 1000BASE-SX | 1 Gigabit Ethernet 1000BASE-LX | 10 Gigabit Ethernet 10GBASE | 40 Gigabet Ethernet 40GBASE-SR4/PLRL4 | 100 Gigabet Ethernet 100GBASE-SR4/IR4 PSM |
| OM3 (Laser Optimized) | 50/125 | Multimode | 2000m | 550m | 550m | 300m | 100m | 100m |
| OM4 (Laser Optimized) | 50/125 | Multimode | 2000m | 550m | 550m | 400m | 150m | 150m |
| Singlemode | 9/125 | Singlemode | 2000m | 5km at 1310nm | 5km at 1310nm | 10km at 1310nm | 1km at PLRL4 | 2km at PSM |
Product details
When both devices expose SC UPC interfaces, this one-metre OM3 cord joins them without any adapter in between. The heading gives LSZH as the jacket and 2.0 mm as the cable size. Multimode OM3 cabling is a common pick for links measured in metres, not kilometres. Support the trunk behind a cassette or panel so the breakout legs are not taking the cable weight. Duplex means a fibre pair, so transmit and receive travel on separate strands. The title lists UPC polish for the near and far connector alike. The heading marks the glass as bend insensitive. The stored sheet adds temperature window -40 to 75 °C.
Key Features
- 1 m OM3 cord, SC UPC at both ends
- LSZH jacket, 2.0 mm cable as titled
- Duplex fibre arrangement
- Stored sheet: temperature window -40 to 75 °C
- Source conflict kept visible: Fiber Class reads G657A1/G657A2, a single-mode designation, on a title that is OM3 multimode
Applications
- Equipment-room patching between SC UPC hardware
- Short multimode backbones between cabinets
- Moves, adds and changes inside a rack
Specifications
| Parameter | Value |
|---|---|
| Connector-1 | SC UPC |
| Connector-2 | SC UPC |
| Fiber Mode | 50/125 μm |
| Fiber Type | Duplex |
| Jacket Material | LSZH |
| Jacket Color | Aqua |
| Mandrel Radius | 15 mm@850nm/7.5 mm@1300nm |
| Macrobend Loss at 850 nm (2 turns) | Induced Attenuation 0.3 dB |
| Macrobend Loss at 1300 nm (2 turns) | Induced attenuation 0.5 dB |
| Operating Temperature | -40 to 75 °C |
| Storage Temperature | -45~85C |
| Fiber Class | G657A1/G657A2 |
| RoHS Compliancy Status | Compliant |
Ordering References
Model and part numbers for ordering reference:
| Reference | Description |
|---|---|
| FT-1M-OM3-9 | F-tone part number |
Contact Us
For pricing, datasheets and OEM/ODM inquiries, contact the F-tone Networks sales team: betty@f-tone.com / una@f-tone.com · WhatsApp: +86 17360698946 (Betty), +86 17761163895 (Una)
More in Fiber Cables & Patch Cords

1U Multi-Service Hosting Chassis
View details →