1x2 1550 nm PM Fiber Circulator, Slow Axis
A 1×2 polarization-maintaining circulator, slow-axis keying, named at 1550 nm. The source table gives Type A, Type B and a 1064 nm column, with a shared 300 mW.
- Center Wavelength, Type A
- 1310 & 1550 nm
- Center Wavelength, Type B
- 1310 & 1550 nm
- Center Wavelength, 1064 column
- 1064 nm
- Operating Wavelength Range, Type A
- ±30 nm
- Operating Wavelength Range, Type B
- ±20 nm
- Operating Wavelength Range, 1064 column
- ±5 nm
Reference model FT-1-2-3 in your inquiry. Datasheets are confirmed offline before order. Full specifications ↓
Technical parameters
| Center Wavelength, Type A | 1310 & 1550 nm |
|---|---|
| Center Wavelength, Type B | 1310 & 1550 nm |
| Center Wavelength, 1064 column | 1064 nm |
| Operating Wavelength Range, Type A | ±30 nm |
| Operating Wavelength Range, Type B | ±20 nm |
| Operating Wavelength Range, 1064 column | ±5 nm |
| Typ. Peak Isolation at 23℃, Type A | 46 dB |
| Typ. Peak Isolation at 23℃, Type B | 30 dB |
| Typ. Peak Isolation at 23℃, 1064 column | 30 dB |
| Min. Isolation at 23℃, Type A | 40 dB |
| Min. Isolation at 23℃, Type B | 20 dB |
| Min. Isolation at 23℃, 1064 column | 25 dB |
| Typ. Insertion Loss at 23℃, Type A | 0.7 dB |
| Typ. Insertion Loss at 23℃, Type B | 0.6 dB |
| Typ. Insertion Loss at 23℃, 1064 column | 1.8 dB |
| Max. Insertion Loss at 23℃, Type A | 0.9 dB |
| Max. Insertion Loss at 23℃, Type B | 0.8 dB |
| Max. Insertion Loss at 23℃, 1064 column | 2.1 dB |
| Min. Extinction Ratio, Type A | 22 dB |
| Min. Extinction Ratio, Type B | 20 dB |
| Min. Extinction Ratio, 1064 column | 20 dB |
| Min. Cross Talk | 50 dB |
| Min. Return Loss | 50 dB |
| Max. Optical Power (CW) | 300 mW |
| Max. Tensile Load | 5 N |
| Fiber Type | PM Panda Fiber |
| Operating Temperature | −5~+70 ℃ |
| Storage Temperature | −40~+85 ℃ |
| Source note, connectors | For a device with connector, IL is 0.3 dB higher, RL is 5 dB lower, ER is 2 dB lower. |
| Source note, key alignment | The default connector key is aligned to slow axis. |
Product details
Unlike the companion page that has no optical table, this slow-axis 1×2 PM circulator ships a three-column source sheet. Type A and Type B both list a 1310 & 1550 nm centre, but the windows differ: ±30 nm versus ±20 nm. At 23 ℃ the Type A column gives typical peak isolation 46 dB, minimum isolation 40 dB, typical insertion loss 0.7 dB and maximum 0.9 dB, with a 22 dB minimum extinction ratio. Type B lists 30 dB typical peak isolation, 20 dB minimum isolation, 0.6 dB typical and 0.8 dB maximum insertion loss, and a 20 dB minimum extinction ratio. A third column is headed only by 1064 nm: ±5 nm, typical peak isolation 30 dB, minimum isolation 25 dB, typical insertion loss 1.8 dB, maximum 2.1 dB, and a 20 dB minimum extinction ratio. Shared rows are 50 dB minimum cross-talk and return loss, 300 mW continuous-wave maximum optical power, 5 N tensile load, PM Panda fibre, −5 to +70 ℃ operation and −40 to +85 ℃ storage. A footnote raises insertion loss by 0.3 dB, lowers return loss by 5 dB and lowers extinction ratio by 2 dB when a connector is fitted, and states that the default connector key is aligned to the slow axis.
Key Features
- Slow-axis 1×2 PM circulator; heading names 1550 nm, while the table also has Type A/B at 1310 & 1550 nm and a 1064 nm column.
- Type A at 23 ℃: typical peak isolation 46 dB, max insertion loss 0.9 dB, min extinction ratio 22 dB.
- Type B at 23 ℃: typical peak isolation 30 dB, max insertion loss 0.8 dB, min extinction ratio 20 dB.
- 1064 nm column: ±5 nm window, max insertion loss 2.1 dB, min isolation 25 dB at 23 ℃.
- Shared: 300 mW CW power, 50 dB min cross-talk and return loss, PM Panda fibre.
Applications
- Slow-axis PM circulation at the 1310/1550 nm windows tabulated for Type A or Type B.
- 1064 nm paths only where the third column of that same table is specified.
Specifications
| Parameter | Value |
|---|---|
| Center Wavelength, Type A | 1310 & 1550 nm |
| Center Wavelength, Type B | 1310 & 1550 nm |
| Center Wavelength, 1064 column | 1064 nm |
| Operating Wavelength Range, Type A | ±30 nm |
| Operating Wavelength Range, Type B | ±20 nm |
| Operating Wavelength Range, 1064 column | ±5 nm |
| Typ. Peak Isolation at 23℃, Type A | 46 dB |
| Typ. Peak Isolation at 23℃, Type B | 30 dB |
| Typ. Peak Isolation at 23℃, 1064 column | 30 dB |
| Min. Isolation at 23℃, Type A | 40 dB |
| Min. Isolation at 23℃, Type B | 20 dB |
| Min. Isolation at 23℃, 1064 column | 25 dB |
| Typ. Insertion Loss at 23℃, Type A | 0.7 dB |
| Typ. Insertion Loss at 23℃, Type B | 0.6 dB |
| Typ. Insertion Loss at 23℃, 1064 column | 1.8 dB |
| Max. Insertion Loss at 23℃, Type A | 0.9 dB |
| Max. Insertion Loss at 23℃, Type B | 0.8 dB |
| Max. Insertion Loss at 23℃, 1064 column | 2.1 dB |
| Min. Extinction Ratio, Type A | 22 dB |
| Min. Extinction Ratio, Type B | 20 dB |
| Min. Extinction Ratio, 1064 column | 20 dB |
| Min. Cross Talk | 50 dB |
| Min. Return Loss | 50 dB |
| Max. Optical Power (CW) | 300 mW |
| Max. Tensile Load | 5 N |
| Fiber Type | PM Panda Fiber |
| Operating Temperature | −5~+70 ℃ |
| Storage Temperature | −40~+85 ℃ |
| Source note, connectors | For a device with connector, IL is 0.3 dB higher, RL is 5 dB lower, ER is 2 dB lower. |
| Source note, key alignment | The default connector key is aligned to slow axis. |
Ordering References
Model and part numbers for ordering reference:
| Reference | Description |
|---|---|
| FT-1-2-3 | F-tone part number |
Contact Us
For pricing, datasheets and OEM/ODM inquiries, contact the F-tone Networks sales team: betty@f-tone.com / una@f-tone.com · WhatsApp: +86 17360698946 (Betty), +86 17761163895 (Una)
More in Products
1x2 10 W High-Power 1550 nm Band Coupler, SMF-28e
View details →1x2 Filter-Type Multimode Fiber Splitter, 850 nm
View details →1x2 Filter-Type Single-Mode Fiber Splitter, 1310/1550 nm
View details →1x2 PLC Splitter, Mini ABS Box Package
View details →1x2 PM PLC Splitter, Slow Axis, ABS Box
View details →
1x2 PLC Splitter, ABS Box Package
View details →1x2 PLC Splitter with Fan-out Kits
View details →1x2 PLC Splitter Tray
View details →
1x2 PLC Splitter, 1U 19-inch Rack-Mount Metal Box
View details →
1x2 Single-Mode FBT Splitter, Three-Window, ABS Box
View details →1x2 PLC Splitter, Mini Plug-in Type
View details →1x2 Single-Mode FBT Splitter, Three-Window Heading, 250 μm Bare Fiber
View details →1x2 Single-Mode FBT Splitter, Three-Window Heading, 900 μm
View details →
1x2 Single-Mode FBT Splitter, Single Window, 900 μm
View details →