Product image coming soon
MODEL · FT-1-2-37

1x2 Single-Mode FBT Splitter, Dual Window, 250 μm Bare Fiber

A 1×2 single-mode dual-window FBT on 250 μm bare fibre. The source table lists 1310 and 1550 nm, Premium typical excess loss 0.1 dB, and Premium/Standard.

Port Configuration
1x2
Operating Wavelength
1310and1550
Operating Bandwidth
±40Wideband,±20Standardband
Typical Excess Loss, Premium / Standard
0.1 dB / 0.15 dB
Split Ratio
1-50 %
Insertion Loss Max 40/60, Premium / Standard
4.7/2.7 / 5.0/2.9

Reference model FT-1-2-37 in your inquiry. Datasheets are confirmed offline before order. Full specifications ↓

Specifications

Technical parameters

Port Configuration1x2
Operating Wavelength1310and1550
Operating Bandwidth±40Wideband,±20Standardband
Typical Excess Loss, Premium / Standard0.1 dB / 0.15 dB
Split Ratio1-50 %
Insertion Loss Max 40/60, Premium / Standard4.7/2.7 / 5.0/2.9
Insertion Loss Max 30/70, Premium / Standard6.0/1.9 / 6.4/2.1
Insertion Loss Max 20/80, Premium / Standard7.9/1.2 / 8.4/1.4
Insertion Loss Max 10/90, Premium / Standard11.3/0.5 / 12.7/0.8
Insertion Loss Max 5/95, Premium / Standard15.2/0.4 / 18.5/0.5
Insertion Loss Max 1/99, Premium / Standard22.5/0.3 / 23.0/0.4
Polarization Sensitivity, Premium / Standard0.1 dB / 0.15 dB
Uniformity, Premium / Standard0.7 dB / 1 dB
Directivity55 dB
Fiber Length1m or Customer Specified
Operating Temperature−20to+85 ℃
Storage Temperature−40to+85 ℃
Overview

Product details

This bare-fibre single-mode 1×2 is specified on a Premium/Standard sheet whose wavelength cell is written “1310and1550”. Operating bandwidth is written “±40Wideband,±20Standardband”. Typical excess loss is 0.1 dB (Premium) and 0.15 dB (Standard). A split-ratio row says 1–50 %, but the insertion-loss header row is empty and there is no 50/50 cell; tabulated pairs start at 40/60 (Premium 4.7/2.7, Standard 5.0/2.9) and continue through 30/70, 20/80, 10/90, 5/95 and 1/99. Polarization sensitivity is 0.1 / 0.15 dB, uniformity 0.7 / 1 dB, and directivity 55 dB. Fibre length is “1m or Customer Specified”. Operation is −20 to +85 ℃ and storage −40 to +85 ℃. Port configuration is 1x2. No bare-fibre outline is stored on this table.

Key Features

  • Bare 250 μm single-mode 1×2; wavelength cell 1310 and 1550 nm.
  • Premium / Standard typical excess loss 0.1 / 0.15 dB.
  • Insertion-loss pairs from 40/60 to 1/99; no 50/50 cell on the source table.
  • Directivity 55 dB; fibre length 1 m or as specified.

Applications

  • Dual-window single-mode splitting on bare 250 μm fibre.
  • Premium or Standard grades at a ratio that the table actually lists.

Specifications

ParameterValue
Port Configuration1x2
Operating Wavelength1310and1550
Operating Bandwidth±40Wideband,±20Standardband
Typical Excess Loss, Premium / Standard0.1 dB / 0.15 dB
Split Ratio1-50 %
Insertion Loss Max 40/60, Premium / Standard4.7/2.7 / 5.0/2.9
Insertion Loss Max 30/70, Premium / Standard6.0/1.9 / 6.4/2.1
Insertion Loss Max 20/80, Premium / Standard7.9/1.2 / 8.4/1.4
Insertion Loss Max 10/90, Premium / Standard11.3/0.5 / 12.7/0.8
Insertion Loss Max 5/95, Premium / Standard15.2/0.4 / 18.5/0.5
Insertion Loss Max 1/99, Premium / Standard22.5/0.3 / 23.0/0.4
Polarization Sensitivity, Premium / Standard0.1 dB / 0.15 dB
Uniformity, Premium / Standard0.7 dB / 1 dB
Directivity55 dB
Fiber Length1m or Customer Specified
Operating Temperature−20to+85 ℃
Storage Temperature−40to+85 ℃

Ordering References

Model and part numbers for ordering reference:

ReferenceDescription
FT-1-2-37F-tone part number

Contact Us

For pricing, datasheets and OEM/ODM inquiries, contact the F-tone Networks sales team: betty@f-tone.com / una@f-tone.com · WhatsApp: +86 17360698946 (Betty), +86 17761163895 (Una)