Product image coming soon
MODEL · FT-1-2-51

1x2 All-Band Fused Coupler, 250 μm Bare Fiber

A 1×2 all-band fused coupler on 250 μm bare fibre, 1260–1620 nm. The source table lists P-grade 50/50 insertion loss ≤3.8 dB and A-grade ≤4.0 dB, with typical.

Type
All Band Coupler (ABC)
Operating Wavelength
1260~1620 nm
Typical Excess Loss, P / A
0.07 dB / 0.1 dB
Insertion Loss 50/50, P / A
≤3.8 dB / ≤4.0 dB
Insertion Loss 45/55, P / A
≤4.45/3.45 dB / ≤4.65/3.65 dB
Insertion Loss 40/60, P / A
≤5.1/3.1 dB / ≤5.3/3.3 dB

Reference model FT-1-2-51 in your inquiry. Datasheets are confirmed offline before order. Full specifications ↓

Specifications

Technical parameters

TypeAll Band Coupler (ABC)
Operating Wavelength1260~1620 nm
Typical Excess Loss, P / A0.07 dB / 0.1 dB
Insertion Loss 50/50, P / A≤3.8 dB / ≤4.0 dB
Insertion Loss 45/55, P / A≤4.45/3.45 dB / ≤4.65/3.65 dB
Insertion Loss 40/60, P / A≤5.1/3.1 dB / ≤5.3/3.3 dB
Insertion Loss 35/65, P / A≤5.7/2.7 dB / ≤5.138/2.90 dB
Insertion Loss 33/67, P / A≤6.0/2.55 dB / ≤6.25/2.75 dB
Insertion Loss 30/70, P / A≤6.4/2.3 dB / ≤6.7/2.5 dB
Insertion Loss 25/75, P / A≤7.4/2.0 dB / ≤7.65/2.2 dB
Insertion Loss 20/80, P / A≤8.3/1.7 dB / ≤8.8/1.8 dB
Insertion Loss 15/85, P / A≤9.9/1.4 dB / ≤10.1/1.50 dB
Insertion Loss 10/90, P / A9.10~11.10≤1.15 / 8.65~11.50≤1.25
Insertion Loss 5/138 (ratio as written on the source table), P / A11.90~14.30≤0.8 / 11.40~14.80≤0.9
Insertion Loss 3/97, P / A13.85~16.75≤0.75 / 13.30~17.35≤0.85
Insertion Loss 2/98, P / A15.45~18.75≤0.7 / 14.75~19.40≤0.8
Insertion Loss 1/99, P / A18.25~21.138≤0.65 / 17.50~22.70≤0.75
PDL, P / A≤0.15 dB / ≤0.20 dB
Directivity≥55 dB
Operating Temperature−40~+85 ℃
Overview

Product details

This all-band 1×2 fused device is offered as 250 μm loose fibre rather than an ABS cassette. The source sheet covers 1260–1620 nm and gives P and A grades. Typical extra loss is 0.07 dB (P) and 0.1 dB (A). For an even split the insertion-loss caps are ≤3.8 dB (P) and ≤4.0 dB (A). Other tabulated ratios run through 1/99, and a ratio cell written “5/138” is kept as written. Polarization-dependent loss and directivity follow that sheet. No package outline beyond the loose-fibre heading is stored.

Key Features

  • All-band 1×2 fused coupler on 250 μm loose fibre; window 1260–1620 nm.
  • P / A typical extra loss 0.07 / 0.1 dB; even-split caps ≤3.8 / ≤4.0 dB.
  • Polarization-dependent loss ≤0.15 / ≤0.20 dB; directivity ≥55 dB; −40 to +85 ℃.
  • The source table’s “5/138” ratio label is reproduced as written.

Applications

  • Broadband splitting on bare 250 μm fibre in a 1260–1620 nm window.
  • P-grade or A-grade builds at a split ratio taken from the source table.

Specifications

ParameterValue
TypeAll Band Coupler (ABC)
Operating Wavelength1260~1620 nm
Typical Excess Loss, P / A0.07 dB / 0.1 dB
Insertion Loss 50/50, P / A≤3.8 dB / ≤4.0 dB
Insertion Loss 45/55, P / A≤4.45/3.45 dB / ≤4.65/3.65 dB
Insertion Loss 40/60, P / A≤5.1/3.1 dB / ≤5.3/3.3 dB
Insertion Loss 35/65, P / A≤5.7/2.7 dB / ≤5.138/2.90 dB
Insertion Loss 33/67, P / A≤6.0/2.55 dB / ≤6.25/2.75 dB
Insertion Loss 30/70, P / A≤6.4/2.3 dB / ≤6.7/2.5 dB
Insertion Loss 25/75, P / A≤7.4/2.0 dB / ≤7.65/2.2 dB
Insertion Loss 20/80, P / A≤8.3/1.7 dB / ≤8.8/1.8 dB
Insertion Loss 15/85, P / A≤9.9/1.4 dB / ≤10.1/1.50 dB
Insertion Loss 10/90, P / A9.10~11.10≤1.15 / 8.65~11.50≤1.25
Insertion Loss 5/138 (ratio as written on the source table), P / A11.90~14.30≤0.8 / 11.40~14.80≤0.9
Insertion Loss 3/97, P / A13.85~16.75≤0.75 / 13.30~17.35≤0.85
Insertion Loss 2/98, P / A15.45~18.75≤0.7 / 14.75~19.40≤0.8
Insertion Loss 1/99, P / A18.25~21.138≤0.65 / 17.50~22.70≤0.75
PDL, P / A≤0.15 dB / ≤0.20 dB
Directivity≥55 dB
Operating Temperature−40~+85 ℃

Ordering References

Model and part numbers for ordering reference:

ReferenceDescription
FT-1-2-51F-tone part number

Contact Us