FT-OM4-1-2 product image - F-tone Networks 1 / 3
MODEL · FT-OM4-1-2

1x2 OM4 Multimode FBT Coupler, Dual Window, 900 μm

Headed as an OM4 dual-window 1×2 multimode FBT on 900 μm fibre. The family table’s 1×2 P column lists 50/50 insertion loss ≤3.7/3.7 dB at “850 or 1310 nm.

Family
1×2(2×2) MMC column of a 1×2/1×3/1×4 family table
Operating Wavelength
850 or 1310 nm, others on request
Operating Bandwidth
±40 nm
Typical Excess Loss, 1×2 P / A
0.4 dB / 0.7 dB
Insertion Loss 50/50, 1×2 P / A
≤3.7/3.7 dB / ≤4.0/4.0 dB
Insertion Loss 40/60, 1×2 P / A
≤4.7/2.7 dB / ≤5.1/3.2 dB

Reference model FT-OM4-1-2 in your inquiry. Datasheets are confirmed offline before order. Full specifications ↓

Specifications

Technical parameters

Family1×2(2×2) MMC column of a 1×2/1×3/1×4 family table
Operating Wavelength850 or 1310 nm, others on request
Operating Bandwidth±40 nm
Typical Excess Loss, 1×2 P / A0.4 dB / 0.7 dB
Insertion Loss 50/50, 1×2 P / A≤3.7/3.7 dB / ≤4.0/4.0 dB
Insertion Loss 40/60, 1×2 P / A≤4.7/2.7 dB / ≤5.1/3.2 dB
Insertion Loss 30/70, 1×2 P / A≤6.0/2.1 dB / ≤6.5/2.4 dB
Insertion Loss 20/80, 1×2 P / A≤7.8/1.4 dB / ≤8.5/1.9 dB
Insertion Loss 10/90, 1×2 P / A≤11.2/0.9 dB / ≤12.4/1.5 dB
Uniformity (50/50), 1×2 P / A≤0.5 dB / ≤0.8 dB
Directivity≥40 dB
Operating Temperature−40 ~ +85 ℃
Fiber Type50/125 or 62.5/125 Multi-Mode or others
Dimensions 250 μm bare fiber (as tabulated)Ф3.0×45 / Ф3.0×54 mm
Dimensions 900 μm loose tube (as tabulated)Ф3.0×54 / Ф4.0×70 mm
Dimensions 0.9/2.0/3.0 mm loose tube (as tabulated)90×20×10 mm
Overview

Product details

The heading names an OM4, dual-window, 900 μm 1×2 multimode fused coupler, but the stored family table does not isolate an OM4 column or a dual-window column. Its wavelength cell is written “850 or 1310 nm, others on request”, and the same sheet is reused across several neighbouring multimode records. Figures below are the 1×2(2×2) P and A columns of that 1×2/1×3/1×4 table. Fibre is listed as 50/125 or 62.5/125 multimode or others — not as an OM4-only row. The 900 μm loose-tube dimension row is written Ф3.0×54 / Ф4.0×70 mm.

Key Features

  • Heading: OM4, dual window, 900 μm; the table wavelength cell is “850 or 1310 nm, others on request”.
  • 1×2 P / A typical extra loss 0.4 / 0.7 dB; even-split caps ≤3.7/3.7 / ≤4.0/4.0 dB.
  • Directivity ≥40 dB; fibre listed as 50/125 or 62.5/125 multimode or others.
  • 900 μm dimension row: Ф3.0×54 / Ф4.0×70 mm, as tabulated.

Applications

  • Multimode 1×2 splitting on 900 μm tails, subject to the family wavelength cell.
  • OM4-labelled orders that must still be confirmed against the 50/125 or 62.5/125 fibre row.

Specifications

ParameterValue
Family1×2(2×2) MMC column of a 1×2/1×3/1×4 family table
Operating Wavelength850 or 1310 nm, others on request
Operating Bandwidth±40 nm
Typical Excess Loss, 1×2 P / A0.4 dB / 0.7 dB
Insertion Loss 50/50, 1×2 P / A≤3.7/3.7 dB / ≤4.0/4.0 dB
Insertion Loss 40/60, 1×2 P / A≤4.7/2.7 dB / ≤5.1/3.2 dB
Insertion Loss 30/70, 1×2 P / A≤6.0/2.1 dB / ≤6.5/2.4 dB
Insertion Loss 20/80, 1×2 P / A≤7.8/1.4 dB / ≤8.5/1.9 dB
Insertion Loss 10/90, 1×2 P / A≤11.2/0.9 dB / ≤12.4/1.5 dB
Uniformity (50/50), 1×2 P / A≤0.5 dB / ≤0.8 dB
Directivity≥40 dB
Operating Temperature−40 ~ +85 ℃
Fiber Type50/125 or 62.5/125 Multi-Mode or others
Dimensions 250 μm bare fiber (as tabulated)Ф3.0×45 / Ф3.0×54 mm
Dimensions 900 μm loose tube (as tabulated)Ф3.0×54 / Ф4.0×70 mm
Dimensions 0.9/2.0/3.0 mm loose tube (as tabulated)90×20×10 mm

Ordering References

Model and part numbers for ordering reference:

ReferenceDescription
FT-OM4-1-2F-tone part number

Contact Us

For pricing, datasheets and OEM/ODM inquiries, contact the F-tone Networks sales team: betty@f-tone.com / una@f-tone.com · WhatsApp: +86 17360698946 (Betty), +86 17761163895 (Una)